The Sensor Library holds the sensors you measure with — their manufacturer, model, serial number, sensitivity, unit and calibration history. Once a sensor is in the library you can assign it to a channel in one click instead of retyping its data for every measurement. For sensors fitted with a TEDS chip, Deepsona can read the sensitivity directly from the sensor.
The window is titled Sensor Library — Deepsona and closes with the Close button.
The editor is organised into five tabs, one per sensor family:
Below the tabs three detail panes show the selected sensor in more depth: Calibration History, Analog Channels / Pulse Geometry and Bus Messages / Bindings.
The status block above the tabs summarises the library, for example
Sensor Library: Analog 12, Pulse 2, CAN/OBD 1, FlexRay 0, Ethernet 0, Channels 18,
with the file path on the following line. When nothing is loaded it reads
"No Sensor Library imported yet."
| Button | Action | Shortcut |
|---|---|---|
| Add analog sensor (wizard) | Starts the two-step wizard for a new analog sensor. | — |
| New library | Creates an empty library. | Ctrl+N |
| Import (.json / .senx) | Opens or merges an existing library file. | Ctrl+O |
| Save library | Writes the library to its file. | Ctrl+S |
| Export as Artemis .senx | Writes a .senx exchange file. | — |
| — | Duplicate the selected sensor | Ctrl+D |
| — | Delete the selected sensor | Del |
Right-clicking any grid offers Add Pulse Sensor, Add CAN/OBD, Add FlexRay, Add Ethernet, Duplicate, Delete and Save As….
Click the add button to start a two-step wizard.
The window Add Analog Sensor — Step 1: Choose Sensor Type presents eight tiles. Selecting one pre-fills sensible defaults so you only have to correct the values that differ from your actual sensor.
| Tile | Description | Pre-filled defaults |
|---|---|---|
| Accelerometer | Uniaxial (1-axis) | CCLD (ICP®), AC, 1 channel Z, 100.0 mV/g → m/s² |
| Accelerometer | Triaxial (X/Y/Z) | CCLD (ICP®), AC, channels X/Y/Z, 100.0 mV/g |
| Microphone | Sound Pressure (Pa) | CCLD (ICP®), AC, 1 channel P, 50.0 mV/Pa → Pa |
| Impact Hammer | Force (N), 1 channel | CCLD (ICP®), AC, 1 channel F, 2.25 mV/N → N |
| Force Gauge | Triaxial (Fx/Fy/Fz) | ±15 V, DC, channels Fx/Fy/Fz, 1.0 mV/N |
| PU / PP Probe | Pressure + Velocity | CCLD (ICP®), AC, channel P 50.0 mV/Pa + channel U 10.0 mV/(m/s) |
| Bridge / Strain | Voltage / Strain | +28 V, DC, 1 channel OUT, 1.0 mV/V → V |
| General | Custom / Other | CCLD (ICP®), AC, 1 channel Ch1, 1000.0 mV/V → V |
Next > is disabled until a tile is selected. Double-clicking a tile selects it and advances in one action.
The window Add Analog Sensor — Step 2: Sensor Properties is divided into three sections. < Back returns to the tile selection; Save to Library adds the sensor.
| Section | Field | Notes |
|---|---|---|
| Sensor Model | Manufacturer | Editable list: PCB Piezotronics, Brüel & Kjær, Kistler, Dytran, IMC, Bosch, National Instruments. You may type any other name. |
| Type / Model No. | Free text. | |
| Power Supply | Editable list: CCLD (ICP®), TEDS, +28 V, ±15 V, Charge, Internal Battery. | |
| Sensor Mode | Editable list: AC, DC, AC Differential. | |
| Calibration Validity | Number of months. Informational. | |
| Is Actuator | Marks an exciter rather than a measuring sensor. | |
| Sensor Instance | Serial Number | Identifies the individual unit. A timestamp-based value is generated for you and should be replaced with the real serial number. |
| Alias / Name | The name shown in lists and in the channel assignment menu. | |
| Calibration Date | Date picker. Shown in the channel tooltip. | |
| Comment | Free text. | |
| Channel Sensitivities | Ch | Channel index, read-only. |
| Axis / Name | e.g. X, Y, Z, P, F. | |
| Nominal Sensitivity | Value from the data sheet. | |
| Calibrated Sensitivity | Value from an actual calibration. When present it takes priority. | |
| Units / Output Unit | e.g. mV/g and m/s². | |
| Quantity Kind / Unit | Physical quantity carried into the recording metadata. |
The Calibration History pane records past calibrations of the selected sensor with columns Date, Ch, Sensitivity and Units. Add an entry with Add Calibration or by typing directly into the empty row at the bottom of the grid. The history is stored with the library and travels with it when you export.
Non-analog sensors are defined on their own tabs and are added from the right-click menu.
| Tab | Columns |
|---|---|
| Pulse Sensors | Name, Quantity, Unit, Pulse Logic, Sensor Type, Tips, Duty, Pulse Step, Transmission, TDC, Dead Time, Comment |
| CAN/OBD | Name, Listen Only, Bit Rate, Bit Rate FD, Protocol, DBC/ARXML, Comments |
| FlexRay | Name, Data Rate, ARXML/XML, Update Bus Params, Comments |
| Ethernet | Name, ARXML, Comments |
A new CAN/OBD entry is created with Protocol CAN, Bit Rate 500 kBit/s
and Listen Only ticked. These fields are free text, not fixed dropdown lists.
The library is an explicit file that you choose yourself — there is no hidden auto-saved location. Keep it with your project so that it travels with the measurement.
| Action | File type | Behaviour |
|---|---|---|
| Save library / Save As… | *.vlsensors.json | Writes the whole library. Default file name Sensor Library.vlsensors.json. |
| Import a Deepsona library | *.vlsensors.json, *.json | Replaces the library currently in memory. |
| Import an exchange library | *.senx | Merges — analog and pulse sensors are appended to the current library. |
| Export | *.senx | Writes an exchange file. Default file name Sensor Library.senx. |
.json library replaces everything currently loaded. Save your work first if
the in-memory library contains sensors you have not written to disk yet. Importing a
.senx file merges instead, and it carries analog and pulse sensors only — bus
definitions are not part of that exchange format.
Mic #4189-A21 — 50.2 mV/Pa [1 ch].The same menu offers Clear sensor link (keep typed values) to detach the sensor while keeping the numbers. If the menu shows "No sensors in library — import a Sensor Library first", load or create a library before assigning.
The library also has bulk helpers at the bottom of the editor: Bind Selected Analog, Auto Bind and Clear Bindings. The Bindings pane shows the resulting Physical / Sensor / Sensitivity mapping.
TEDS (IEEE 1451.4) sensors carry their own identification data. Deepsona reads it and fills the channel row automatically, so a TEDS microphone or accelerometer needs no manual entry at all.
[TEDS] Ch 3: PCB Piezotronics model333B32 S/N12345 tmpl25 → 100.4 mV/g.
The chip icon in the Channel Settings header bar — Read all TEDS —
probes every enabled analog channel in turn. The log summarises the result:
[TEDS] Read All: 3/4 channel(s) decoded TEDS sensor.
| Channel field | Behaviour |
|---|---|
| Sensitivity | Always overwritten with the value stored in the sensor. |
| Unit | Set from the sensor: Pa for microphones, m/s² or g for accelerometers, N for force sensors. |
| Sensor Type | Set only if it is still empty, derived from the unit (Pa → Mic, g / m/s² → Trial Acc, N → Force). |
The manufacturer, model number and serial number read from the sensor are reported in the Acquisition Log so you can record them alongside the measurement.
| Message or symptom | Cause and remedy |
|---|---|
[TEDS] Ch n: no sensor / not decodable. | No sensor connected, the sensor has no TEDS chip, or the cable is faulty. Check the connection and retry. |
[TEDS] Ch n: probe failed (channel/driver may not support TEDS). | That input or acquisition path does not offer TEDS. Enter the sensitivity manually, assign a library sensor, or calibrate. |
[TEDS] Ch n: probe sent. If sensor detected, row will auto-fill in next snapshot. | Normal on some acquisition paths: the read is asynchronous. Wait a moment for the row to update. |
| TEDS read never completes | The read can take up to 20 seconds per channel. If it still hangs, stop Preview, unplug and replug the sensor, then retry. |
| The unit changed unexpectedly after a TEDS read | Expected — the unit stored in the sensor takes priority over the unit implied by the sensor type. Adjust the Sensor Type afterwards if needed. |
| Assign-sensor menu is empty | No library is loaded. Use Import in the Sensor Library, or create sensors with the wizard. |
| "Failed to import Sensor Library: …" | The file is not a valid library file, or is open in another application. Check the extension and try again. |
| Sensitivities look right but levels are wrong | Check the Unit column too — sensitivity and unit must be consistent (mV/Pa with Pa, mV/g with g). |
Related: Recorder Setup · Calibration · RPM and Bus Channels